• Laminar Flow Clean Bench Solutions

    Vertical & Horizontal Airflow for ISO Class 5 Work Zones
    HEPA-filtered workstations for localized protection of non-hazardous samples and contamination-sensitive products in laboratories and precision manufacturing.

    EXPLORE CLEAN BENCH SOLUTIONS
    Laminar Flow Clean Bench/Cabinet

What Is a Laminar Flow Clean Bench?

A laminar flow clean bench provides a localized clean working area by directing HEPA-filtered, unidirectional airflow across the work surface.

Available in vertical and horizontal airflow configurations, these workstations help reduce airborne particle contamination during non-hazardous sample handling, inspection and precision assembly.

When properly configured and performance-tested, a clean bench can provide an ISO Class 5 working zone without requiring the entire surrounding room to meet the same cleanliness classification.

Which Laminar Flow Clean Bench Is Right for Your Application?

Compare airflow direction, HEPA filter position and typical applications to select a suitable clean bench for your process.

Comparison

Vertical Flow

Horizontal Flow

Airflow Direction Top to bottom Rear to front
HEPA Position Above work zone Rear of work zone
Typical Applications Non-hazardous sample handling and clean assembly Electronics, optics and precision assembly
Key Consideration Avoid obstructing downward airflow with tall objects Keep rear-to-front airflow unobstructed

Not sure which airflow configuration fits your process?
Share your application and workspace requirements with our engineering team.

Why Cleanroom Designers, Contractors & EPCs Choose Flair?

Flair supports cleanroom projects with application-based equipment selection, configurable work zones, installation coordination and agreed factory inspection services.

  • Application-Based Selection

    Selection support based on process, airflow direction and workspace requirements.

  • Custom Work Zone Design

    Configurable dimensions, materials and workstation layouts for project-specific applications.

  • Easy Project Integration

    Equipment footprint, electrical supply and maintenance access considered during project planning.

  • Factory Inspection Support

    Pre-shipment functional checks and inspection records based on agreed project requirements.

Key Engineering Features Across Our Clean Bench Range

AC centrifugal fan or EC EBM motor, according to IEEE specification and requirements, low noise

Efficient & Low-Noise Fan System

Fan options balance airflow performance, energy consumption and noise levels for continuous clean bench operation.

Clean Bench Intelligent Control System

Intelligent Control System

Available touchscreen controls enable adjustment of fan speed, lighting and operating settings for different application requirements.

Clean Bench Unidirectional Airflow

Engineered Unidirectional Airflow

Optimized airflow distribution supports uniform, HEPA-filtered air supply across vertical or horizontal working zones.

Clean Bench Dual-Stage Filtration System

HEPA Filtration with Pre-Filter Options

Pre-filtration and HEPA filtration work together to capture airborne particles and help extend HEPA filter service life.

Clean Bench Cleanable Work Zone

Cleanable & Ergonomic Work Zone

Smooth work surfaces, practical access and integrated lighting support cleaning and comfortable daily operation.

Clean Bench Maintenance Access-1

Service-Friendly Maintenance Access

Accessible pre-filters, HEPA filters and service components help simplify routine inspection and maintenance.

Features and available options may vary by model and project configuration.

How Vertical and Horizontal Clean Benches Work?

HEPA-filtered airflow is directed vertically or horizontally across the work zone to help minimize airborne particle contamination.

Vertical laminar flow clean bench Working principle

Vertical Laminar Flow

Room air enters through the upper pre-filter, passes through the fan and overhead HEPA filter, then flows vertically downward across the working area to help minimize airborne particle contamination.

Horizontal laminar flow clean bench Working principle

Horizontal Laminar Flow

Room air enters through the lower intake and pre-filter, passes through the fan and rear HEPA filter, then flows horizontally across the working area toward the front opening.

Custom Clean Bench Engineering and Laboratory Integration

Flair offers custom laminar flow clean benches tailored to work zone dimensions, airflow requirements and project layouts.

Work Zone & Construction

  • Custom working area dimensions (W × D × H)
  • Stainless steel or powder-coated steel construction
  • Worktop height, side panels and mobility options

Airflow & Control

  • Airflow velocity and filtration specifications
  • Fan speed and control system options
  • Lighting, power outlets and utility configurations

Project Integration

  • Electrical supply and connection requirements
  • Equipment footprint and maintenance clearances
  • Project-specific GA drawings and agreed inspection records

Reference GA Drawings — Custom Dimensions and Configurations Available

Laminar Flow Clean Bench Applications

Flair clean benches support contamination-sensitive processes in pharmaceutical and medical device manufacturing, electronics assembly and non-hazardous laboratory work.

clean bench for Medical Device & Pharmaceutical

Pharmaceutical and Medical Device Manufacturing

Localized clean airflow for non-hazardous component preparation, assembly and inspection.

clean-bench for Electronics & Precision Assembly

Electronics & Precision Assembly

HEPA-filtered work zones for sensitive electronic components, optical parts and precision assembly.

clean bench for Laboratory & Research

Laboratory & Research

Clean working areas for non-hazardous sample preparation, inspection and research activities.

FAQs

Answers to common questions about clean bench selection, ISO Class 5 performance, customization, testing and maintenance.

The clean bench is a work area or work earea ensures that the work surface is constantly flooded with HEPA-filtered air in a laminar flow. Unlike a biological safety cabinet, the clean bench protects the work on the work surface, but not personnel or the surrounding environment from aerosols created on the work surface. The HEPA air filter can trap 99.999% of particles with a diameter greater than 0.3 microns.

The Vertical Laminar Flow benches are manufactured with rear wall perforations to reduce turbulence by removing a small amount of air at the rear of the cabinet.

Vertical flow clean bench

The Horizontal Laminar flow benches do not directly impinge upon the work surface or encounter turbulence but rather is smoothly drawn across it.

Horizontal flow clean bench

Yes. A properly designed and configured laminar flow clean bench can provide a localized ISO Class 5 work zone.

However, HEPA filtration alone does not guarantee ISO Class 5 performance. Cleanliness classification should be verified through airborne particle testing in accordance with ISO 14644-1 under defined operating conditions.

ISO Class 5 applies to the tested work zone, not automatically to the surrounding room. Additional qualification may be required for regulated applications.

There are severl differences between clean  bench & Bioasafety cabinet

The clean bench ensures that the work surface is constantly flooded with HEPA-filtered air in a laminar flow. It is in a positive environment.

The clean bench protects the work on the work surface, but not personnel or the surrounding environment from aerosols created on the work surface.

The Clean bench do not provide any protection to the worker. They are designed to provide a sterile environment to protect the product. Air potentially contaminated with infectious agents may be blown towards the worker.

Biosafety cabinets protect the product as well as the user and the environment. They operate under negative air pressure , protecting the user from exposure to aerosolized infectious agents. The air sucked into the hood is sterilized by high efficiency particulate air (HEPA) filtration before being exhausted out, thereby protecting the environment.

Biosafety Cabinets are similar to the Laminar Air Flow cabinets. They too contain HEPA filters but there is one dissimilarity that Biosafety Cabinets offers complete protection to the users against harmful pathogens, since the contaminated air is filtered before it can come in contact with the users.

Many users don’t know the difference between clean bench and laminar flow hood, There are a lot of misconceptions about them:

Clean bench

A clean bench is generally a self-contained workstation with an integrated work surface, filtration system and airflow controls.

Laminar flow hood

A ceiling-mounted laminar flow hood supplies filtered air over a designated process area, production line or workstation without necessarily including an integrated bench.

Both can provide localized clean airflow, but their installation methods, working area coverage and integration requirements differ. Selection depends on the process layout and cleanliness requirements.

Yes. Flair offers configurable clean benches to accommodate different workspace and project requirements.

Depending on the model, available options may include overall and work zone dimensions, stainless steel or powder-coated construction, vertical or horizontal airflow designs, fan speed controls, lighting, electrical outlets and mobility features.

Project-specific GA drawings can be provided to support equipment selection and installation planning.

Factory inspection and testing can be arranged according to the clean bench model and agreed project requirements.

Available checks may include visual inspection, electrical and control system operation, fan performance and airflow velocity measurements. HEPA filter integrity testing and additional performance verification can be specified where applicable.

Relevant inspection records and technical documentation can be supplied as agreed before shipment.

Routine maintenance includes checking and cleaning or replacing pre-filters, inspecting airflow performance and monitoring the condition of the HEPA filtration system.

HEPA filter replacement procedures depend on the clean bench design and filter mounting arrangement. Replacement should be performed by qualified personnel following the manufacturer’s instructions.

After replacement, airflow performance and filter integrity should be verified as required. Maintenance intervals depend on operating conditions, usage and filter condition.

Need a Laminar Flow Clean Bench for Your Project?

Share your application, airflow direction, work zone dimensions and project requirements. Our team can recommend a suitable clean bench configuration and provide technical drawings and quotation support.

Copyright © 2018 - 2026 Shenzhen Flair Equipment Co., Ltd.